Comparison of Water Sorption of Two Injection Acrylic Resins with a Conventional Pressure-Packed Acrylic Resin

Ehsan Ghasemi1, Ramin Mosharraf2, Siavash Mirzaei3*
1 Assistant Professor, Dental Material Research Center, Department of Prosthodontics, School of  Dentistry, Isfahan University of Medical Sciences, Isfahan, Iran
2 Professor, Dental Materials Research Center, Department of Prosthodontics, School of Dentistry,  Isfahan University of Medical Sciences, Isfahan, Iran
3 Dentist, Private Office, Isfahan, Iran

Citation: Ghasemi E, Mosharraf R, Mirzaei S (2021) Comparison of Water Sorption of Two Injection Acrylic Resins with a Conventional Pressure-Packed Acrylic Resin. SciTech Central Dentistry 2021. 

Received: February 04, 2021         Accepted: February 06, 2021         Published: February 06, 2021

Abstract

Background and Aim: Water sorption is one of the most important properties that affects the quality of a prosthesis, and subsequently, the quality of treatment, and patient’s quality of life. The aim of this study was to determine and compare the water sorption of two types of poly methyl methacrylate (PMMA) using the injection-molding systems with a traditional acrylic resin base material.
Materials and  Methods: In this in vitro, experimental study, three groups of PMMA (n=10), consisting of two groups of  injection molded PMMA samples (Vertex Castavaria and Ivo-Base High-Impact) were used for two  different injection molding techniques and one group of conventional pressure-packed PMMA (Meliodent  Heat Cure) was used for the conventional pressure-packed technique. After processing, 30 specimens were stored in distilled water at 37°C for 30 days. The water sorption test was then performed. Statistical analysis was carried out using SPSS version 23.0 via the Kruskal-Wallis and Mann-Whitney tests (α=0.05). 
Results: The mean value of water sorption was 17.88±1.08 µg/mm3 for IvoBase specimens, 28.45±2.19µg/mm3 for Vertex specimens, and 21.76 ±3.26 µg/mm3 for Meliodent specimens (P<0.001 for Ivobase-Vertex, P <0.007 for Ivobase-Meliodent, and P<0.001 for Vertex-Meliodent).  
Conclusion: Water sorption of IvoBase was significantly lower than that of other materials. Despite such a significant difference, all of them completely fulfilled the requirements of EN ISO 20795-1:2008.  
 
Key Words: Adsorption, Injections, Polymethyl Methacrylate